Rack cooling
State-of-the-art solutions for your IT infrastructure

In times of digitization, industry 4.0 and big data, the amount of data to be processed is increasing daily. As a result, energy-efficient data centers and server rooms are becoming increasingly important. Increasing heat loads and environmental requirements for air conditioning are conflicting goals. After all, 3 % of the energy consumed worldwide flows into data centers. Innovative solutions, with the possibility of coupling to free cooling or other renewable solutions, enable you to realize the optimum of your plant and master the challenges of the future. Break new ground in IT air conditioning with energy-efficient and individual solutions and maximum system availability!

PRODUCT

RackCooler – SideCooler

FIELD
  • EDP and IT infrastructure
ADVANTAGES
  • Location-independent placement of your racks possible
  • Maximum system availability through fail-safe properties and the design of redundancies
  • Low payback period by reducing current energy costs by up to 80 %
  • Retrofittable for existing racks and various rack makes
  • Universally applicable, as no raised floor is necessary
  • Resource-saving operation through elimination of latent cooling
  • High Density Cooling

BRIEF DESCRIPTION

The SideCooler works on the principle of direct rack cooling. The cooling elements are mounted next to your racks and cool the racks in a closed air circulation. In a redundancy arrangement, in alternating sequence of rack and SideCooler, two-sided cooling of the racks is possible. The cooling capacity is supplied according to your wishes and requirements of system water circuits, chillers, free cooling or other renewable solutions.

PRODUCT

RackCooler – FrontCooler

FIELD
  • EDP and IT infrastructure
ADVANTAGES
  • Maximum system availability throughfail-safe properties and the design of redundancies
  • Constant cooling capacity over the entire rack height
  • Low payback period by reducing current energy costs by up to 80 %
  • Retrofittable for existing racks and various rack makes
  • Open air circulation for cooling the entire server room possible.

BRIEF DESCRIPTION

The FrontCooler cooling system arranged at the front of the racks directs the cold air directly to the consumers in front of the 19-inch rack level. The particularly energy-efficient precision cooling units are connected between the racks. Both closed air circulation in the rack and open circulation with cooling of the entire server room are possible. By means of a cold aisle enclosure, the catalytic air and warm air areas are consistently separated from one another. The cooling capacity is supplied according to your wishes and requirements by system water circuits, chillers, free cooling or other renewable solutions.

PRODUCT

CoolManager

FIELD
  • Paper industry
  • Industrial solutions
  • EDP and IT infrastructure
ADVANTAGES
  • Highest security and availability through state-of-the-art technology
  • Optimum capacity utilisation through individual production
  • Low payback period by reducing current energy costs by up to 80 %
  • Hydraulic separation of the cold water networks protects against contamination of the medium.

BRIEF DESCRIPTION

In water-cooled rack cooling or climatic chambers, the CoolManager with pump and heat exchanger stations enables a safe separation between your primary and secondary cold water network.

Curious about more?
Visit our social media platforms!

You need support in the air conditioning
of your operating resources?

Make a non-binding inquiry now!